Dantherm MVHR - HCV 700 | Residential Ventilation Unit
Description
Description
The Dantherm HCV 700 is a high-performance residential ventilation unit designed for Australian houses, villas, and apartments up to 450m2 or more. Equipped with intelligent demand-controlled ventilation, EC fan motors, and high-efficiency heat recovery, the HCV 700 delivers fresh, filtered air while minimising energy use.
Ideal for wall installation, the unit includes a standard mounting rail and all necessary components for a fast, efficient setup. It features integrated controls, optional advanced filtration, and modes tailored for Australian climate comfortincluding Summer and Fireplace Mode for better indoor living throughout the year.
Whether you're upgrading your home's air quality or designing a new energy-efficient space, the Dantherm HCV 700 is the premium choice for modern ventilation needs.
Features
- Demand-Controlled Ventilation: Built-in humidity sensor automatically reduces power use during low ventilation periods.
- Summer Mode: Disables the supply fan so cooler outside air can flow through open windows, lowering indoor temperature.
- Fireplace Mode: Temporarily creates positive pressure to improve chimney draft and performance.
- High-Efficiency Heat Recovery: Recovers up to 85% of heat from outgoing air, reducing heating demand.
- EC Fan Motors: Extremely low energy use with Specific Power Input (SPI) of just 0.22 m3/h.
- Easy Installation: Integrated air pressure spigots and standard wall rail allow fast and accurate commissioning.
- Highly Customisable: Compatible with a wide range of internal and external accessories.
- Complete Wall Kit: Supplied with standard wall bracket and drainage hose for plug-and-play operation.
Specifications
Specifications
Model | HCV 700 |
---|---|
Max. Achievable Flow @ 100Pa (V100Pa) | 550 m³/h |
Max. Declared Flow @ 100Pa (Vmax.rated) | 450 m³/h |
Recommended Operating Range | 80 – 450 m³/h |
EN 13141-7 Reference Flow @ 50Pa (VREF) | 315 m³/h |
Thermal Efficiency (EN13141-7) | 85% |
Specific Power Input (SFP) | 0.22 m³/h |
Leakage Rate (EN13141-7) | <2% (Class A1) |
Filters (ISO16890) | ISO Coarse 75% (Opt: ePM1>50%) |
Filters (EN779) | G4 (Opt: F7) |
Install Ambient Temp | +12 to +50 °C |
Outdoor Temp w/o Preheater | -12 to +50 °C |
Outdoor Temp with Preheater | -20 to +50 °C |
Max Extract Air Humidity | 10 g/kg |