How Heat Transfer Systems Move Warm Air Through Your Home?
This is the reality for many Australian homes. We are great at heating one room, but we struggle to heat the whole house. You end up with one sauna and...
Vortice
Vortice Lineo Inline Mixed Flow AC Fan - Lineo 250 | 250MM (10" Inch)
Air Flow 1470 M³/H | Power Consumption 150W | IPX5
Vortice
Vortice Lineo Inline Mixed Flow AC Fan - Lineo 200 | 200MM (8" Inch)
Air Flow 1135 M³/H | Power Consumption 110W | IPX5
Vortice
Vortice Lineo Inline Mixed Flow AC Fan - Lineo 315 | 315MM (12" Inch)
Air Flow 2740 M³/H | Power Consumption 360W | IPX5
Vortice
Vortice Lineo Inline Mixed Flow AC Fan - Lineo 150 | 150MM (6" Inch)
Air Flow 550 M³/H | Power Consumption 58W | IP44
Blauberg
Blauberg Turbo EC Mixed Flow Fan - 315MM (12" Inch) | w/ Speed Controller & Lead and Plug
Air Flow 1970 M³/H | Power Consumption 284W | IPX4
Blauberg
Blauberg Turbo EC Mixed Flow Fan - 150MM (6" Inch) | w/ Speed Controller & Lead and Plug
Air Flow 600 M³/H | Power Consumption 55W | IPX4
Blauberg
Blauberg Turbo EC Mixed Flow Fan - 250MM (10" Inch) | w/ Speed Controller & Lead and Plug
Air Flow 1285 M³/H | Power Consumption 169W | IPX4
AC Infinity
AC Infinity Inline EC Exhaust Fan Cloudline Pro T10 - 250MM (10" Inch)
Air Flow 2040 M³/H | Power Consumption 255W | IP44
AC Infinity
AC Infinity Inline EC Exhaust Fan Cloudline Pro T6 - 150MM (6" Inch)
Air Flow 688 M³/H | Power Consumption 70W | IP44
Ventair
Ventair Inline Mixed Flow AC Exhaust Fan - 200 | 200MM ( 8" Inch) | w/ Mounting Bracket
Air Flow 852 M³/H | Wattage 130W | IPX4
Ventair
Ventair Inline Mixed Flow AC Exhaust Fan - 150 | 150MM ( 6" Inch) | w/ Mounting Bracket
Air Flow 561 M³/H | Wattage 50W | IPX4
Ventair
Ventair Axial inline Exhaust Fan - Inline 100 | 100MM (4" Inch)
Air Flow 119 M³/H | Wattage 18W | IP44
Fantech
Fantech Provent In-line Duct Mounted AC Exhaust Fan - 100MM (4" Inch)
Air Flow 245 M³/H | Power Consumption 24W | IP44
Fantech
Fantech Provent In-line Duct Mounted AC Exhaust Fan - 200MM (8" Inch)
Air Flow 1040 M³/H | Power Consumption 120W | IP44
Fantech
Fantech Provent In-line Duct Mounted AC Exhaust Fan - 150MM (6" Inch) | with Run-On-Timer
Air Flow 562 M³/H | Power Consumption 50W | IP44
Fantech
Fantech Provent In-line Duct Mounted AC Exhaust Fan - 200MM (8" Inch) | with Run-On-Timer
Air Flow 1040 M³/H | Power Consumption 120W | IP44
Fantech
Fantech Provent In-line Duct Mounted AC Exhaust Fan - 150MM (6" Inch)
Air Flow 562 M³/H | Power Consumption 50W | IP44
Fantech
Fantech Provent In-line Duct Mounted AC Exhaust Fan - 125MM (5" Inch)
Air Flow 320 M³/H | Power Consumption 30W | IP44
Fantech
Fantech Jetline In-line Duct Mounted AC Exhaust Fan -100MM (4" Inch)
Air Flow 260 M³/H | Power Consumption 19W | IP44
Fantech
Fantech Jetline Eco In-line Duct Mounted EC Exhaust Fan - 125MM (5" Inch)
Air Flow 390 M³/H | Power Consumption 40W | IP44
Fantech
Fantech Jetline Eco In-line Duct Mounted EC Exhaust Fan - 315MM (12" Inch)
Air Flow 1570 M³/H | Power Consumption 215W | IP44
Fantech
Fantech Jetline In-line Duct Mounted AC Exhaust Fan - 150MM (6" Inch)
Air Flow 750 M³/H | Power Consumption 83W | IP44
Fantech
Fantech Jetline Eco In-line Duct Mounted EC Exhaust Fan - 200MM (8" Inch)
Air Flow 1050 M³/H | Power Consumption 125W | IP44
Fantech
Fantech Jetline Eco In-line Duct Mounted EC Exhaust Fan - 100MM (4" Inch)
Air Flow 260 M³/H | Power Consumption 19W | IP44
Fantech
Fantech Jetline In-line Duct Mounted AC Exhaust Fan - 315MM (12" Inch)
Air Flow 1610 M³/H | Power Consumption 215W | IP44
Fantech
Fantech Jetline In-line Duct Mounted AC Exhaust Fan - 125MM (5" Inch)
Air Flow 420 M³/H | Power Consumption 40W | IP44
Fantech
Fantech Jetline Eco In-line Duct Mounted EC Exhaust Fan - 250MM (10" Inch)
Air Flow 1270 M³/H | Power Consumption 160W | IP44
Phresh Hyperfan
Phresh Hyperfan EC Exhuast Fan v2 w/ Controller - 150MM (6" Inch)
Air Flow 560 M³/H | Power Consumption 42W | IPX2
Measure your room (Length × Width × Height) to get the volume, then multiply by the air changes per hour (ACH) you need: Airflow (m³/h) = Room volume × ACH. Bathrooms usually need 10–20 ACH, laundries and kitchens 15–30 ACH, and grow tents even higher.
Air exchange (air changes per hour) is how many times the full room volume is replaced each hour. It’s critical for removing steam, smells and humidity, and for preventing mould and condensation.
AC fans use a traditional AC motor, are cheaper and simple to run. EC fans use a high-efficiency brushless EC motor with electronics, are quieter, more efficient, and allow much finer speed control.
Use only controllers made for AC motors, such as step/transformer controllers, specific AC speed controllers, or the built-in 2-speed function (if provided). The wrong controller can cause noise, poor performance or motor damage.
EC fans are best paired with 0–10V, PWM or dedicated EC/smart controllers. These give smooth, stepless speed control and often allow temperature, humidity or timer-based automation.
Choose AC if you want a budget-friendly fan with simple on/off or 2-speed control. Choose EC if you want top efficiency, quiet operation and precise or smart control, especially for 24/7 or climate-critical applications.
Yes. Long duct runs, tight bends, small duct sizes and filters all reduce airflow. Match the duct size to the fan, keep runs as short and straight as possible, and minimise sharp bends.
Yes, a correctly sized inline fan can exhaust from two or more rooms using junctions (Y/T pieces). Ensure the total room volume and required ACH match the fan capacity, and use dampers to balance airflow.
Most inline fans sit in the roof space or ceiling void, connected to an intake grille inside and ducted to an external vent. The air should always be discharged outside, not into the roof cavity.
Look for insulated or mixed-flow models, check the dBA noise rating, and consider an EC fan so you can run it at lower speeds. Using flexible connectors and anti-vibration mounts also helps reduce noise.